The new 430 Series II Power Quality and Energy Analyzers offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses.
- Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
- Power inverter efficiency: Simultaneously measure AC output power and DC input power for power electronics systems using optional DC clamp.
- PowerWave data capture: capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
- Waveform capture: capture 100/120 cycles (50/60Hz) of each event that is detected in all modes, without set-up.
- Automatic Transient Mode: capture 200 kHz waveform data on all phases simultaneously up to 6 kV.
- Fully Class-A compliant: conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.
- Mains signaling: measure interference from ripple control signals at specific frequencies.
- Troubleshoot real-time: Analyze the trends using the cursors and zoom tools.
- Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
- Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
- Automatic Trending: Every measurement is always automatically recorded, without any set-up.
- System-Monitor: Ten power quality parameters on one screen according to EN50160 power quality standard.
- Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals.
- View graphs and generate reports: With included analysis software.
- Battery life: Seven hours operating time per charge on Li-ion battery pack.
1 mV/A to 1 V/A and custom for use with optional ac or dc clamps Input impedance: 1 MΩ
Bandwidth: > 10 kHz
Scaling: 1:1, 10:1, 100:1, 1,000:1 10,000:1 and variable
Wiring configurations
1Ø + NEUTRAL Single phase with neutral
1Ø SPLIT PHASE Split phase
1Ø IT NO NEUTRAL Single phase system with two phase voltages without neutral
3Ø WYE Three phase four wire system WYE
3Ø DELTA Three phase three wire system Delta
3Ø IT Three phase system without neutral WYE
3Ø HIGH LEG Four wire three phase Delta system with center tapped high leg
3Ø OPEN LEG Open delta three wire system with 2 transformer windings
2-ELEMENT Three phase three wire system without current sensor on phase L2/B (2 watt meter method)
2½-ELEMENT Three phase four wire system without voltage sensor on phase L2/B
INVERTER EFFICIENCY dc voltage and current input with ac output power (automatically displayed and selected in Inverter Efficiency mode)
size 256 x 169 x 64 mm Shipping Weight 24.4900 Power Supply NiMH Battery Manufacturer Fluke MPN FLUKE-435-II Manufacturer Warranty Three-year warranty Mitchell Catalog Number 7P435JF,8P435JF,9P435JF, WB345JF upc code 0 95969 61556 3