Equipped with 8 independent channels, the 3-phase PowerGuide® 4400 is part of the only family of advanced power monitoring instruments to incorporate a color touch screen into its lightweight design. Automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data in seconds. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy and load balancing. The Intelligent AnswerModule® feature provides consultant-like analysis of sag directivity, capacitor switching transient identification/directivity and motor analysis/reporting.
FEATURES
- Eight channels, 4 voltage & 4 current – AC or DC
- Intuitive color touch screen user interface
- Light weight — About 4 pounds, 2 kg — with rugged rubber boot
- Samples at 256 samples/cycle
- Independent voltage & current triggering, cross triggering
- Automatic setups – Start monitoring in seconds with only a few keystrokes
- Annunciator reports – Instant, color coded event alarms & reports
- Intelligent AnswerModule’s - Sag Directivity, Motor Health and Capacitor Switching
- Detailed event characterization of RMS variations and transients
- THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd
- Remote communications—RS-232, Ethernet or USB
- Battery or AC powered - Built in 2Hr UPS battery with charger
- 4GB Compact Flash Memory
- Available languages — English, French, Italian, German, Spanish, Swedish, Polish, Thai, Korean, Finnish, Japanese, Chinese (Traditional and Simplified)
- Dran-View® PC software enabled (Windows XP, Vista, 7, 8)
- Complies with IEEE 1159 (PQ), IEEE 519 (Harmonics), IEEE 1453 (Flicker)
- Measures flicker according to IEC 61000-4-15; measures harmonics according to IEC 61000-4-7
- Complies with IEC 61000-4-30 Class A (certified by an independent laboratory), EN50160
- Measures a wide range of parameters, including W, VA, VAR, PF, DPF, Demand, Energy, crest factor, K factor, transformer derating factor, telephone interference factor and more
- UL and CE certified
APPLICATIONS
· Power Quality Surveys and Diagnostics
- Motor testing & diagnosis
- Fault recording
- Inrush testing for transformers, motors, etc.
- Energy management & load surveys
- Data logging
- Harmonic analysis
- Alternative energy production – Solar, Wind – Panel strings, batteries, inverters, grid interconnect
- Compliance testing
- Flicker testing
- Capacitor testing
|